MG1-C Coaxial Level Probe for Liquids and Solids

MG1-C Coaxial Probe TDR (Time Domain Reflectometry or Wave Guided Radar) Level Transducer for Liquids and Solids, Tank Measurement from 0.1m to 6m, ATEX Approved

If the liquid is viscose (up to 500 cPs), has a low dielectric constant or there is a disturbance such as a stirrer in the tank, then the Flowtechnik MG1-C coaxial TDR probe is the one to choose. Its in-built settling tube and reference electrode effectively cancel out interference and allow reliable detection of thicker and low dielectric medias like oils, even in non-conductive tanks, open channels and pits.

  • Media types: Most liquids (water to thick oils etc) and solids in powder or pellet form
  • Level measurement in: Metallic tanks, non-metallic tanks, open channels and pits
  • Measuring ranges: 0.1-6m
  • Connection: ¾” BSP or NPT (other connection styles available on request)
  • Materials: Stainless Steel, PEEK
  • Accuracy: ±3mm
  • Resolution: < 1mm
  • Response time: 0.5 s
  • Minimum dielectric constant: >1.4
  • Maximum viscosity: 500 cPs
  • Fluid temperature: -15 to +150oC (Viton seal), -40 to +130oC (EPDM seal)
  • Pressure rating: -1 to +40 Bar
  • Power supply: 12-30 Vdc
  • Output: 4-20 mA with HART and PNP transistor
  • Ingress protection: IP68
  • Options: ATEX approved version for EEx ia operation
Contact Us

Quotation request